ETC RSN-LV R2 Response 0-10V Gateway Rev 2 4267A1102
Previous Product Next ProductETC
36 in stock
ETC
ETC RSN-LV R2 Response 0-10V Gateway Rev 2 4267A1102
Get a competitive "QUOTE" on ETC product ........ call 516.766.2266
All Bulbs will beat pricing from all competitors.
Quantity Per Case: 1
ETC RSN-LV R2 Response 0-10V (Low Voltage) Gateway Rev 2
The Response 0-10V Gateway accepts streaming ACN (sACN) or DMX control input to provide 24 outputs of 0-10V control. It is ideal for both retrofit and new power-control system installations that require four-wire LED drivers and fluorescent ballasts. The Gateway also accepts a contact input to set each channel’s output to a programmed level for use in emergency lighting applications.
APPLICATIONS
• Houses of worship
• Hotels
• Convention centers
• Meeting rooms
• House lighting
• Museums
• Themed environments
FEATURES
• 24 independent 0-10V control outputs
• DMX or sACN control input
• Configurable dimming curve per output
• Configurable high-end trim
• Contact input for emergency lighting
• Onboard configuration using four-button interface.
• Onboard display for status and configuration
• Power and network status indicators
• 18-24vDC power input
SPECS
FUNCTIONAL
• Supports sACN control input (ANSI E1.31)
• Supports USITT DMX512-A control input (ANSI E1.11)
• Supports 0-10V sink control (IEC60929 Annex E) and 0-10V source control (ANSI E1.3)
• Supports per-address- or per-universe-level priority
• Configurable dimming curve per channel
- Linear
- Mod-Square
- Custom (Future)
MECHANICAL
• Intuitive four-button interface
• Onboard display for identification, status and configuration
• Extruded aluminium enclosure • Network and power activity indicators
- Blue power indicator
- Green and orange network activity indicator
• Female RJ45 for connection to lighting network
• Pluggable terminals provided for all wiring connections
• Selection switch for emergency input configuration
- Normally Open, Normally Closed or Off
• Trim pot for configuration of 0-10V maximum voltage, +/- 1V
• 10 unit DIN enclosure
• Mounting complies with DIN43880 (35/7.5 rail)
ENVIRONMENTAL
• Ambient operating temperature: 0° to 40°C (32° to 104°F)
• Operating humidity: 5% - 95% non-condensing
• Storage temperature: -40° to 70°C (-40° to 158°F)
ELECTRICAL
• Compliant with IEEE 802.3i for 10BASE-T, 802.3u for 100BASE-TX
• 18-24vDC power input using two-pin pluggable connection
• Maximum 18W current draw at 18-24V
• 24 0-10V outputs, each supporting voltage source or sink connections, 50mA maximum current per output
• RoHS compliant (lead-free)
• CE compliant and ETL listed
DMX INPUT PORT
• Optically-isolated input from the Gateway electronics
• Withstands fault voltages of up to 250VAC
• Integrated DMX/RDM termination
CONFIGURATION
• Onboard configuration using intuitive four-button interface
• Configuration provided using Net3 Concert software (Future)
• Configurable starting address
• Up to four sources may be combined to the network with each source or address allowed an independent priority
ADDITIONAL INFORMATION
DMX512
Often shortened to DMX (Digital Multiplex), this communication protocol is used mainly to control dimmers and multi-parameter fixtures. A universe of DMX is defined as 512 channels. DMX sends a nearly continuous stream of level information for each control channel. It is a form of RS-485 digital serial communication.
sACN
Streaming ACN (ANSI E1.31), sends DMX-style control over TCP/ IP networks. It provides a fast and efficient mechanism to transport the well-understood DMX protocol over Ethernet using an industry standard protocol.
ACN
Architecture for Control Networks (ANSI E1.17) is a standard for high-speed bidirectional communication over TCP/IP on Ethernet network infrastructure. ACN is an open suite of protocols used between network devices for the purposes of greater and more adaptive control.
NET3
ETC’s enhanced implementation of the standard ACN Protocol Suite (ANSI E1.17 and E1.31) including additional communication protocols for specialized applications and support of legacy systems.
Returns Policy
You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).
You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).
If you need to return an item, simply login to your account, view the order using the 'Complete Orders' link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.
Shipping
We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.